| Quality Australian Chillers for Data Centres | |||||||||||||||||||
|
Data Centre equipment cooling |
|||||||||||||||||||
|
|
|||||||||||||||||||
|
Data Centre equipment cooling and rack cooling requirements are unique Stability of temperature is crucial.
Chilled water is pumped through close control air
handling units for server room cooling and
plumbed under floor for direct rack cooling. Chillers then provide the water cooling using a refrigeration system that collects heat from the water and discharges it as waste hot air.
Some rack cooling systems include a chiller water connection for each cabinet or enclosure while others have a hot row/cold row configuration, or a single cooling rack in line for a number of server racks.
Air-cooled chillers from Summit Matsu Chilling Systems are supplied in a modular fashion for a n+1 solution which allows for redundancy and can be integrated with a chiller tank and pump unit as a package.
Because data centre infrastructure must often be retro-fitted to existing buildings the modular chiller configuration allows installation in limited space. Chiller air discharge can be either horizontal or vertical.
Multiple refrigeration systems can be built into each chiller for added redundancy and can be staged on a lead-lag arrangement to spread equal run hours across all compressors and chillers.
Screw compressors are used for high efficiency and PLCs (Programmable Logic Controllers) can link back to virtually any control system in the data centre.
The regular chiller controls can protect the machine from multiple fault events including loss of water flow, air flow, refrigeration high or low pressure, loss of phase or incorrect phase rotation as well as standard motor protection for temperature and current.
Because rack cooling and equipment cooling can operate with higher water temperatures than air conditioning systems, Summit Matsu Chilling Systems chillers are optimised for performance at higher temperatures which increases the energy efficiency of the water cooling system.
Naturally all Summit Matsu Chilling Systems chillers are built for hot Australian conditions.
Summit Matsu Chilling Systems also offer a "whole of life" chiller plant solution including extended warranty and service.
Please contact Summit Matsu Chilling Systems on Tel: +61 2 9698 4666, Fax: +61 2 9698 4688, or email via the contact us form to discuss your specific data centre rack cooling or equipment cooling chiller needs.
Please provide information on water temperatures for supply and return and also the flow rate - this should allow the engineers at Summit Matsu Chilling Systems to quickly give an indication of the appropriate chiller model.
Photos: Details of some smaller Matsu chillers are available by clicking here or select from above.
|
|||||||||||||||||||
|